3.Install the required Backup software (SUNWsbuc, SUNWsbus1, SUNWsbun, and
SUNWsbus2) on the system you want to designate as the Backup server.
Before you install the Backup software on the server, read the following sections in
this Solstice Backup 5.1 Installation and Release Notes:
-"Server Software Installation Requirements" on page 16
-"Server Software Installation Example" on page 26
Install all the Backup software on the server at the same time. If you choose to install
only selected software packages on the server, you must install them in the
following order:
a.The client software package (SUNWsbuc)
b. The storage node software package (SUNWsbun)
c. The server software package (SUNWsbus1)
d. The optional device drivers package (SUNWsbus2)
4.Install the Backup client (SUNWsbuc) software on machines with the same
operating system and hardware platform as the Backup server.
You can choose to install the software locally on each client or remotely through a
mounted network file system (NFS) partition.
Before you install the Backup software on the clients on your network, read the
following sections in this Solstice Backup 5.1 Installation and Release Notes:
-"Client Software Installation Requirements" on page 18
-"Client Software Installation Example" on page 30
5.If you purchased an enabler for storage node support, install the Backup client
(SUNWsbuc), storage node (SUNWsbun), and device driver (SUNWsbus2) software on
the machines that you want to designate as storage nodes.
To find the latest information about supported devices, obtain the latest
Compatibility Guide from the Legato web site ( http://www.legato.com/
documents/NetWorker/compat-guide.html/).
6.Configure the devices for the Backup server and storage nodes.
See "Configuring Autochanger Support" on page 42. For more detailed information,
refer to the autochanger and silo chapters in the Solstice Backup 5.1 Administration
Guide.
|
|
|
|